Ysi Professional Plus Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature Ysi Professional Plus. YSI Professional Plus User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 2 - CONTENTS

1011Number Key Description6Right ArrowUse to navigate right in alpha/numeric entry screens. Can be pressed simultaneously with Backlight key to incre

Pagina 3

1213alpha/nuMerIc entryThe numeric screens will display numbers only (shown on the left). Alpha/numeric screens will display numbers acr

Pagina 4 - WAR R ANTY

1415GlpThe GLP or ‘Good Laboratory Practice’ file saves detailed information about calibrations. It also includes diagnostic information

Pagina 5 - GETTING STARTED

1617An example of a GLP record(Operation performed is single point % DO Calibration)*** Calibrate – DO% *** Date 02/03/09 MM/DD/YYTime

Pagina 6

1819lanGuaGeThe Pro Plus can be configured to display all text in English, Spanish, French, German, Portuguese, Italian, Norwegian, Si

Pagina 7

2021unIt IdUnit ID is used to identify instruments in the Data Manager software program that was included with your instrument. It is also used to id

Pagina 8 - QUATRO CABLE

2223SETUP  DISSOLVED OXYGENPress Sensor , highlight Setup and press enter. Next, highlight DO and press enter.Enabled allows you to enable or

Pagina 9 - SENSOR STORAGE

2425Local DO allows for localized DO% measurements. This sets the calibration value to 100% regardless of the altitude or barometric pressure. Hig

Pagina 10 - Menu layout

2627Auto Stable and Hold All Readings enabled, then the display will hold the readings once DO and pH have both reached their Auto Stable

Pagina 11 - SYSTEM MENU

2829After selecting your User ID and/or Probe ID if appropriate, highlight DO and press enter. Highlight DO % and press enter to confirm. The instrum

Pagina 12

CONTENTSWarranty ...iIntroduction ...

Pagina 13 - GLP SETTINGS

3031Highlight Calibration value and press enter to manually input the sample’s dissolved oxygen value. Highlight Accept Calibration and press en

Pagina 14

3233Highlight Calibration Value and press enter to manually enter the correct “true” barometric pressure. Next, highlight Accept Calibration, an

Pagina 15 - AUTO STABLE, AND CALIBRATION

3435DISPLAY  CONDUCTIVITYPress Sensor , highlight Display and press enter. Highlight Conductivity and press enter. Highlight Sp. Conductance (Spec

Pagina 16 - SETUP  DISSOLVED OXYGEN

3637CALIBRATION  CONDUCTIVITYThe 6051030 ISE/conductivity cable has a specialized calibration container that resembles a large test tube. This calib

Pagina 17 - DISPLAY  DISSOLVED OXYGEN

3839pHpH sensors can be used on 60510-X, 6051020-X, 6051030-X, 6051010-X, and Quatro cables. If using a 605103 pH/ORP combination sensor on a

Pagina 18 - SALINITY CORRECTION

4041Sensitivity selected by User % Data Variance Threshold100 - Most Sensitive, Sensitivity bar is set to the far right0.025%75 0.39375%50 1.5%25 1.13

Pagina 19

4243If a sensor is Enabled that isn’t connected to the instrument, the display will show an unstable false reading, ?????, or ----- next to the units.

Pagina 20 - CALIBRATION  BAROMETER

4445Sensitivity selected by User % Data Variance Threshold100 - Most Sensitive, Sensitivity bar is set to the far right0.05%75 0.62525%50 1.275%25 1.8

Pagina 21 - SETUP  CONDUCTIVITY

4647Enabled allows you to enable or disable the ISE function and select which ISE sensor is installed on the cable. Highlight Enabled and press enter

Pagina 22 - AUTO STABLE  CONDUCTIVITY

4849CALIBRATION  AMMONIUM, NITRATE, CHLORIDEThe 6051030 ISE/conductivity cable has a specialized calibration container that resembles a large test tu

Pagina 23 - CALIBRATION  CONDUCTIVITY

Dissolved Oxygen (DO) ...21Barometer ...

Pagina 24 - AUTO STABLE  H

5051After selecting your User ID and/or Probe ID if appropriate, highlight Ammonium, Nitrate, or Chloride to access the appropriate calibration,

Pagina 25 - CALIBRATION  H

5253the sky and then twist tying, zip tying, or rubber banding the bulkhead to the cable. Making a simple curve to the cable without bending or break

Pagina 26 - SETUP  ORP

5455time qualifier you would like to set, press enter, and use the numeric entry screen to select the date/time you wish to view.After making your sel

Pagina 27 - CALIBRATION  ORP

5657usInG the coMMunIcatIons saddleWARNING: DO NOT connect the Communications Saddle to your PC before installing Data Manager. The Communication Sa

Pagina 28

5859confIGure InstruMentsData Manager allows for easy and quick configuration of single or multiple instruments. Once you have uploaded a

Pagina 29 - Preparing Chloride Standards

6061GENERAL MAINTENANCE  SENSOR PORTSIt is important that the entire sensor connector end be dry when installing, removing or replacing.

Pagina 30 - TAKING MEASUREMENTS

6263cap. If the cathode remains tarnished, contact YSI Technical Support or the Authorized dealer where you purchased the instrument.Silv

Pagina 31 - FILES AND SITE LISTS

6465SENSOR MAINTENANCE  CONDUCTIVITYThe openings that allow sample access to the conductivity electrodes should be cleaned regularly. The small clea

Pagina 32 - DESKTOP SOFTWARE

6667sensor can be regenerated by washing with alcohol and/or gently polishing with fine emery paper in a circular motion to remove any deposits or dis

Pagina 33 - ManaGe loGGed data

6869Long-term Storage - ORPTo store, remove the sensor from the cable and seal the vacant port with the provided plug. Fill the original sh

Pagina 34 - AND STORAGE

iWAR R ANTYThe YSI Professional Plus Instrument (Pro Plus) is warranted for three (3) years from date of purchase by the end user against

Pagina 35 - Membrane Cap Installation

7071dIssolVed oxyGenThe dissolved oxygen sensors will use Probe Current (DO uA) and Probe Slope (%/uA) as part of their GLP file records. The followi

Pagina 36

7273Sensor Part Number Description605105**** Chloride (ISE)605106**** Nitrate (ISE)605780 Self-Stirring BOD sensor005560 Conductivity/Temperature sens

Pagina 37 - SENSOR MAINTENANCE  CHLORIDE

7475Accessory Part Number Description603069 Belt clip063517 Ultra clamp063507 Tripod clamp603062 Cable management kit605978 Weight, sensor/cable, 4.9

Pagina 38

7677Harmonized Standards: •EN61326-1:2006,Electricalequipmentformeasurement, control, and laboratory use – EMC requirements – Part 1: General Req

Pagina 39 - TROUBLESHOOTING

7879The undersigned hereby declares on behalf of the named manufacturer under our sole responsibility that the listed product conforms with the Austra

Pagina 40 - ACCESSORIES / PART NUMBERS

Item # 605596Rev DDrawing # A605596 March 2009©2009 YSI Incorporated.

Pagina 41

ii1INTRODUCTIONThank you for purchasing the YSI Professional Plus (Pro Plus). The Pro Plus features a waterproof (IP-67) case, backlit display and

Pagina 42 - DECLARATION OF CONFORMITY

23recommended for lab use or controlled conditions where a more rugged, field cable is not necessary. These cables include:Cable number 605107 1-me

Pagina 43

451010 dual cablePort 1 Options Port 2 OptionspH pHORP ORPpH or pH/ORP* pH or pH/ORP*ammonium ammoniumchloride chloridenitrate nitratenone (port plug)

Pagina 44 - CONTACT INFORMATION

67Figure 2. The image on the left shows a clean, dry sensor being aligned with the bulkhead. On the right, the sensor has been pushed into the bulkh

Pagina 45 - ©2009 YSI Incorporated

89CONNECTING THE CABLE TO AN INSTRUMENTTo connect a cable, align the keys on the cable connector to the slots on the instrument connect